EXPOSURE TEST STATION SIMULATED MARINE ENVIRONMENT AT KAWASAKI PLANT
- Main Page
- Technology & Products
- Marine Steel Structures
- Exposure Test Station Simulated Marine Environment At Kawasaki Plant
Test plant-based data collection
Basic data is collected at a test plant that simulates an ocean environment. Evaluation including the weld points needed to create the actual structure is ongoing.
Seawater exposure test area



Test piece (stainless steel pipe pile cover)

Splash zone

Tidal zone

Submerged zone
After one year of exposure | NAS 254N | NAS 185N | SUS 316L |
---|---|---|---|
State with marine organisms stuck to the pile |
![]() |
![]() |
![]() |
After removal of the marine organisms |
![]() No crevice corrosion |
![]() No crevice corrosion |
![]() Crevice corrosion occurred |
After one year of exposure | State with marine organisms stuck to the pile | After removal of the marine organisms |
---|---|---|
NAS 254N |
![]() |
![]() No crevice corrosion |
NAS 185N |
![]() |
![]() No crevice corrosion |
SUS 316L |
![]() |
![]() Crevice corrosion occurred |
Surface of weld points on various stainless steel pipe piles. Super stainless steel has excellent resistance to seawater, with no crevice corrosion forming even where barnacles have adhered to the surface, including at weld points.
Other tests
To investigate corrosion resistance of various types of steel under actual conditions, we also conduct exposure tests on small pieces inside the seawater exposure test area.

Atmospheric exposure test

Seawater spray test
Related Information
Nippon Yakin products
Technology & Products
Core Technologies
Products
- High-Performance Alloys
- Stainless Steels
-
Stainless Steel Floor Plates